Load transfer on instrumented prestressed ground anchors in sandy soil

abstract: This study evaluates load variations in instrumented prestressed ground anchors installed in a bored pile retaining wall system in sandy soil. Data were collected from instrumentation assembled in the bonded length of three anchors, which were monitored during pullout tests and during different construction phases of the retaining wall system. Instrumentation consisted of electrical resistance strain gauges positioned in five different sections along the bonded length. Skin friction distributions were obtained from the field load measurements. Results showed that the skin friction followed a non-uniform distribution along the anchor bonded length. The mobilized skin friction concentrated more intensely on the bonded length half closest to the unbonded length, while the other half of the bonded length developed very small skin friction. The contribution of the unbonded length skin friction to the overall anchor capacity was significant and this should be accounted for in the interpretation of routine anchor testing results. Displacements applied to the anchor head were sufficient to mobilize the ultimate skin friction on the unbonded length, but not on the bonded length. Performance of loading-unloading stages on the ground anchor intensified the transfer of load from the unbonded length to the bonded length. Long-term monitoring of the anchor after lock-off revealed that the load at the anchor bonded length followed a tendency to reduce with time and was not significantly influenced by the retaining wall construction phases.

Saved in:
Bibliographic Details
Main Authors: Sousa,Alex Micael Dantas de, Costa,Yuri Daniel Jatobá, Florêncio,Luiz Augusto da Silva, Costa,Carina Maria Lins
Format: Digital revista
Language:English
Published: IBRACON - Instituto Brasileiro do Concreto 2021
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952021000600206
Tags: Add Tag
No Tags, Be the first to tag this record!