Auditory evoked potential P300 in adults: reference values

ABSTRACT Objective To establish reference intervals for cognitive potential P300 latency using tone burst stimuli. Methods This study involved 28 participants aged between 18 and 59 years. P300 recordings were performed using a two-channel device (Masbe, Contronic). Electrode placement was as follows: Fpz (ground electrode), Cz (active electrode), M1 and M2 (reference electrodes). Intensity corresponded to 80 dB HL and frequent and rare stimulus frequencies to 1,000Hz and 2,000Hz, respectively. Stimuli were delivered binaurally. Results Mean age of participants was 35 years. Average P300 latency was 305ms. Conclusion Maximum acceptable P300 latency values of 362.5ms (305 + 2SD 28.75) were determined for adults aged 18 to 59 years using the protocol described.

Saved in:
Bibliographic Details
Main Authors: Didoné,Dayane Domeneghini, Garcia,Michele Vargas, Oppitz,Sheila Jacques, Silva,Thalisson Francisco Finamôr da, Santos,Sinéia Neujahr dos, Bruno,Rúbia Soares, Filha,Valdete Alves Valentins dos Santos, Cóser,Pedro Luis
Format: Digital revista
Language:English
Published: Instituto Israelita de Ensino e Pesquisa Albert Einstein 2016
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000200015
Tags: Add Tag
No Tags, Be the first to tag this record!