Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel

This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.

Saved in:
Bibliographic Details
Main Authors: Lacerda,José C. de, Freitas,Lucas L. de, Brito,Rogério F., Moura Filho,Francisco, Teixeira,Ricardo L.P.
Format: Digital revista
Language:English
Published: ABM, ABC, ABPol 2021
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S1516-14392021000100215
record_format ojs
spelling oai:scielo:S1516-143920210001002152021-02-01Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless SteelLacerda,José C. deFreitas,Lucas L. deBrito,Rogério F.Moura Filho,FranciscoTeixeira,Ricardo L.P. intergranular corrosion degree of sensitization DL-EPR This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.info:eu-repo/semantics/openAccessABM, ABC, ABPolMaterials Research v.24 n.1 20212021-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215en10.1590/1980-5373-mr-2020-0408
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Lacerda,José C. de
Freitas,Lucas L. de
Brito,Rogério F.
Moura Filho,Francisco
Teixeira,Ricardo L.P.
spellingShingle Lacerda,José C. de
Freitas,Lucas L. de
Brito,Rogério F.
Moura Filho,Francisco
Teixeira,Ricardo L.P.
Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
author_facet Lacerda,José C. de
Freitas,Lucas L. de
Brito,Rogério F.
Moura Filho,Francisco
Teixeira,Ricardo L.P.
author_sort Lacerda,José C. de
title Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
title_short Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
title_full Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
title_fullStr Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
title_full_unstemmed Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
title_sort comparative study between sensitization degree of the 0.4% mo austenitic stainless steel and uns s31803 duplex stainless steel
description This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.
publisher ABM, ABC, ABPol
publishDate 2021
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215
work_keys_str_mv AT lacerdajosecde comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel
AT freitaslucaslde comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel
AT britorogeriof comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel
AT mourafilhofrancisco comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel
AT teixeiraricardolp comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel
_version_ 1756420900230529024