Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.
Main Authors: | , , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
ABM, ABC, ABPol
2021
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S1516-14392021000100215 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S1516-143920210001002152021-02-01Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless SteelLacerda,José C. deFreitas,Lucas L. deBrito,Rogério F.Moura Filho,FranciscoTeixeira,Ricardo L.P. intergranular corrosion degree of sensitization DL-EPR This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.info:eu-repo/semantics/openAccessABM, ABC, ABPolMaterials Research v.24 n.1 20212021-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215en10.1590/1980-5373-mr-2020-0408 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
Lacerda,José C. de Freitas,Lucas L. de Brito,Rogério F. Moura Filho,Francisco Teixeira,Ricardo L.P. |
spellingShingle |
Lacerda,José C. de Freitas,Lucas L. de Brito,Rogério F. Moura Filho,Francisco Teixeira,Ricardo L.P. Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel |
author_facet |
Lacerda,José C. de Freitas,Lucas L. de Brito,Rogério F. Moura Filho,Francisco Teixeira,Ricardo L.P. |
author_sort |
Lacerda,José C. de |
title |
Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel |
title_short |
Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel |
title_full |
Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel |
title_fullStr |
Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel |
title_full_unstemmed |
Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel |
title_sort |
comparative study between sensitization degree of the 0.4% mo austenitic stainless steel and uns s31803 duplex stainless steel |
description |
This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC. |
publisher |
ABM, ABC, ABPol |
publishDate |
2021 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215 |
work_keys_str_mv |
AT lacerdajosecde comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel AT freitaslucaslde comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel AT britorogeriof comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel AT mourafilhofrancisco comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel AT teixeiraricardolp comparativestudybetweensensitizationdegreeofthe04moausteniticstainlesssteelandunss31803duplexstainlesssteel |
_version_ |
1756420900230529024 |