Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel

This study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.

Saved in:
Bibliographic Details
Main Authors: Lacerda,José C. de, Freitas,Lucas L. de, Brito,Rogério F., Moura Filho,Francisco, Teixeira,Ricardo L.P.
Format: Digital revista
Language:English
Published: ABM, ABC, ABPol 2021
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392021000100215
Tags: Add Tag
No Tags, Be the first to tag this record!