Short implants to support mandibular complete dentures - photoelastic analysis

Abstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis was performed with the photoelastic method (n = 6). Each model comprised 4 implants with the same length and diameter connected by a chromium-cobalt bar that simulates a fixed denture. A 0.15 kg force was applied at the end of the cantilever (15 mm), and the maximum shear stress was recorded around the distal and subsequent implants. The stress values were determined, and the quantitative data (Fringes®) were submitted to statistical analysis with one-way ANOVA and the Dunnett test (p < 0.05). It was observed that the reduction in implant length increased stress values with a significant difference (p < 0.05) between CG Ci7 and Ci5, while the increase in implant diameter reduced the stress values without any differences found between short and long implants. Implants with 5 and 7 mm with regular diameter increased stress levels while short implants with larger diameters experienced similar stress to that of longer implants.

Saved in:
Bibliographic Details
Main Authors: PIMENTEL,Marcele Jardim, SILVA,Wander José da, DEL BEL CURY,Altair Antoninha
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Pesquisa Odontológica - SBPqO 2017
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100216
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S1806-83242017000100216
record_format ojs
spelling oai:scielo:S1806-832420170001002162017-02-21Short implants to support mandibular complete dentures - photoelastic analysisPIMENTEL,Marcele JardimSILVA,Wander José daDEL BEL CURY,Altair Antoninha Dental Implants Bone Resorption Denture Complete Abstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis was performed with the photoelastic method (n = 6). Each model comprised 4 implants with the same length and diameter connected by a chromium-cobalt bar that simulates a fixed denture. A 0.15 kg force was applied at the end of the cantilever (15 mm), and the maximum shear stress was recorded around the distal and subsequent implants. The stress values were determined, and the quantitative data (Fringes®) were submitted to statistical analysis with one-way ANOVA and the Dunnett test (p < 0.05). It was observed that the reduction in implant length increased stress values with a significant difference (p < 0.05) between CG Ci7 and Ci5, while the increase in implant diameter reduced the stress values without any differences found between short and long implants. Implants with 5 and 7 mm with regular diameter increased stress levels while short implants with larger diameters experienced similar stress to that of longer implants.info:eu-repo/semantics/openAccessSociedade Brasileira de Pesquisa Odontológica - SBPqOBrazilian Oral Research v.31 20172017-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100216en10.1590/1807-3107bor-2017.vol31.0018
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author PIMENTEL,Marcele Jardim
SILVA,Wander José da
DEL BEL CURY,Altair Antoninha
spellingShingle PIMENTEL,Marcele Jardim
SILVA,Wander José da
DEL BEL CURY,Altair Antoninha
Short implants to support mandibular complete dentures - photoelastic analysis
author_facet PIMENTEL,Marcele Jardim
SILVA,Wander José da
DEL BEL CURY,Altair Antoninha
author_sort PIMENTEL,Marcele Jardim
title Short implants to support mandibular complete dentures - photoelastic analysis
title_short Short implants to support mandibular complete dentures - photoelastic analysis
title_full Short implants to support mandibular complete dentures - photoelastic analysis
title_fullStr Short implants to support mandibular complete dentures - photoelastic analysis
title_full_unstemmed Short implants to support mandibular complete dentures - photoelastic analysis
title_sort short implants to support mandibular complete dentures - photoelastic analysis
description Abstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis was performed with the photoelastic method (n = 6). Each model comprised 4 implants with the same length and diameter connected by a chromium-cobalt bar that simulates a fixed denture. A 0.15 kg force was applied at the end of the cantilever (15 mm), and the maximum shear stress was recorded around the distal and subsequent implants. The stress values were determined, and the quantitative data (Fringes®) were submitted to statistical analysis with one-way ANOVA and the Dunnett test (p < 0.05). It was observed that the reduction in implant length increased stress values with a significant difference (p < 0.05) between CG Ci7 and Ci5, while the increase in implant diameter reduced the stress values without any differences found between short and long implants. Implants with 5 and 7 mm with regular diameter increased stress levels while short implants with larger diameters experienced similar stress to that of longer implants.
publisher Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publishDate 2017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100216
work_keys_str_mv AT pimentelmarcelejardim shortimplantstosupportmandibularcompletedenturesphotoelasticanalysis
AT silvawanderjoseda shortimplantstosupportmandibularcompletedenturesphotoelasticanalysis
AT delbelcuryaltairantoninha shortimplantstosupportmandibularcompletedenturesphotoelasticanalysis
_version_ 1756431604655325184