Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle

ABSTRACT The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG’s serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.

Saved in:
Bibliographic Details
Main Authors: Palhão,M.P., Guimarães,C.R.B., Lima,J.F.J.F.M., Mendonça,M.R., Fernandes,C.A.C., Neves,J.P., Garcia,J.A.D., Gioso,M.M., Miglino,M.A., Viana,J.H.M.
Format: Digital revista
Language:English
Published: Universidade Federal de Minas Gerais, Escola de Veterinária 2019
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0102-09352019000601909
record_format ojs
spelling oai:scielo:S0102-093520190006019092019-12-10Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattlePalhão,M.P.Guimarães,C.R.B.Lima,J.F.J.F.M.Mendonça,M.R.Fernandes,C.A.C.Neves,J.P.Garcia,J.A.D.Gioso,M.M.Miglino,M.A.Viana,J.H.M. color doppler PAGs timed embryo transfer ABSTRACT The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG’s serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.info:eu-repo/semantics/openAccessUniversidade Federal de Minas Gerais, Escola de VeterináriaArquivo Brasileiro de Medicina Veterinária e Zootecnia v.71 n.6 20192019-12-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909en10.1590/1678-4162-10698
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Palhão,M.P.
Guimarães,C.R.B.
Lima,J.F.J.F.M.
Mendonça,M.R.
Fernandes,C.A.C.
Neves,J.P.
Garcia,J.A.D.
Gioso,M.M.
Miglino,M.A.
Viana,J.H.M.
spellingShingle Palhão,M.P.
Guimarães,C.R.B.
Lima,J.F.J.F.M.
Mendonça,M.R.
Fernandes,C.A.C.
Neves,J.P.
Garcia,J.A.D.
Gioso,M.M.
Miglino,M.A.
Viana,J.H.M.
Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
author_facet Palhão,M.P.
Guimarães,C.R.B.
Lima,J.F.J.F.M.
Mendonça,M.R.
Fernandes,C.A.C.
Neves,J.P.
Garcia,J.A.D.
Gioso,M.M.
Miglino,M.A.
Viana,J.H.M.
author_sort Palhão,M.P.
title Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_short Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_full Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_fullStr Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_full_unstemmed Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_sort efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
description ABSTRACT The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG’s serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.
publisher Universidade Federal de Minas Gerais, Escola de Veterinária
publishDate 2019
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909
work_keys_str_mv AT palhaomp efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT guimaraescrb efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT limajfjfm efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT mendoncamr efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT fernandescac efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT nevesjp efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT garciajad efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT giosomm efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT miglinoma efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
AT vianajhm efficacyandlimitationsofdifferentapproachestoanticipatethediagnosisofpregnancyincattle
_version_ 1756395808754761728