Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center
Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.
Main Authors: | , , , , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
2015
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100008 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S0100-39842015000100008 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S0100-398420150001000082015-04-14Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging centerSantana,Priscila do CarmoOliveira,Paulo Marcio Campos deMamede,MarceloSilveira,Mariana de CastroAguiar,PolyannaReal,Raphaela VilaSilva,Teógenes Augusto da Dosimetry Thermoluminescence dosimetry PET/CT Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. info:eu-repo/semantics/openAccessPublicação do Colégio Brasileiro de Radiologia e Diagnóstico por ImagemRadiologia Brasileira v.48 n.1 20152015-02-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100008en10.1590/0100-3984.2013.1821 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
Santana,Priscila do Carmo Oliveira,Paulo Marcio Campos de Mamede,Marcelo Silveira,Mariana de Castro Aguiar,Polyanna Real,Raphaela Vila Silva,Teógenes Augusto da |
spellingShingle |
Santana,Priscila do Carmo Oliveira,Paulo Marcio Campos de Mamede,Marcelo Silveira,Mariana de Castro Aguiar,Polyanna Real,Raphaela Vila Silva,Teógenes Augusto da Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center |
author_facet |
Santana,Priscila do Carmo Oliveira,Paulo Marcio Campos de Mamede,Marcelo Silveira,Mariana de Castro Aguiar,Polyanna Real,Raphaela Vila Silva,Teógenes Augusto da |
author_sort |
Santana,Priscila do Carmo |
title |
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center |
title_short |
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center |
title_full |
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center |
title_fullStr |
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center |
title_full_unstemmed |
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center |
title_sort |
ambient radiation levels in positron emission tomography/computed tomography (pet/ct) imaging center |
description |
Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. |
publisher |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publishDate |
2015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100008 |
work_keys_str_mv |
AT santanaprisciladocarmo ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter AT oliveirapaulomarciocamposde ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter AT mamedemarcelo ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter AT silveiramarianadecastro ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter AT aguiarpolyanna ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter AT realraphaelavila ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter AT silvateogenesaugustoda ambientradiationlevelsinpositronemissiontomographycomputedtomographypetctimagingcenter |
_version_ |
1756386823430471680 |