Corneal biomechanical features in patients with ankylosing spondylitis

ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Cabuk,Kubra Serefoglu, Üstün,Emine Isil, Atalay,Kursat, Kirgiz,Ahmet, Aydin,Rukiye
Format: Digital revista
Langue:English
Publié: Conselho Brasileiro de Oftalmologia 2017
Accès en ligne:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
id oai:scielo:S0004-27492017000500009
record_format ojs
spelling oai:scielo:S0004-274920170005000092017-11-09Corneal biomechanical features in patients with ankylosing spondylitisCabuk,Kubra SerefogluÜstün,Emine IsilAtalay,KursatKirgiz,AhmetAydin,Rukiye Spondylitis, ankylosing Corneal biomechanics Corneal tomography Severity of illness index ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.info:eu-repo/semantics/openAccessConselho Brasileiro de OftalmologiaArquivos Brasileiros de Oftalmologia v.80 n.5 20172017-10-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009en10.5935/0004-2749.20170075
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Cabuk,Kubra Serefoglu
Üstün,Emine Isil
Atalay,Kursat
Kirgiz,Ahmet
Aydin,Rukiye
spellingShingle Cabuk,Kubra Serefoglu
Üstün,Emine Isil
Atalay,Kursat
Kirgiz,Ahmet
Aydin,Rukiye
Corneal biomechanical features in patients with ankylosing spondylitis
author_facet Cabuk,Kubra Serefoglu
Üstün,Emine Isil
Atalay,Kursat
Kirgiz,Ahmet
Aydin,Rukiye
author_sort Cabuk,Kubra Serefoglu
title Corneal biomechanical features in patients with ankylosing spondylitis
title_short Corneal biomechanical features in patients with ankylosing spondylitis
title_full Corneal biomechanical features in patients with ankylosing spondylitis
title_fullStr Corneal biomechanical features in patients with ankylosing spondylitis
title_full_unstemmed Corneal biomechanical features in patients with ankylosing spondylitis
title_sort corneal biomechanical features in patients with ankylosing spondylitis
description ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.
publisher Conselho Brasileiro de Oftalmologia
publishDate 2017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009
work_keys_str_mv AT cabukkubraserefoglu cornealbiomechanicalfeaturesinpatientswithankylosingspondylitis
AT ustunemineisil cornealbiomechanicalfeaturesinpatientswithankylosingspondylitis
AT atalaykursat cornealbiomechanicalfeaturesinpatientswithankylosingspondylitis
AT kirgizahmet cornealbiomechanicalfeaturesinpatientswithankylosingspondylitis
AT aydinrukiye cornealbiomechanicalfeaturesinpatientswithankylosingspondylitis
_version_ 1756373241005342720