Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper

The data folder is includes the five different data sets used in the paper along with a metadata file, where the different features are explained.

Saved in:
Bibliographic Details
Main Authors: Ferrer-Cid, Pau, Barceló-Ordinas, José María, García Vidal, Jorge, Ripoll, Anna, Viana, Mar
Other Authors: European Commission
Format: dataset biblioteca
Language:English
Published: 2020
Subjects:Air pollution, Calibration, http://aims.fao.org/aos/agrovoc/c_228, http://aims.fao.org/aos/agrovoc/c_36549, http://aims.fao.org/aos/agrovoc/c_28279, Polución del aire, Calibración, Sensores,
Online Access:http://hdl.handle.net/10261/217106
http://dx.doi.org/10.13039/501100000780
Tags: Add Tag
No Tags, Be the first to tag this record!
id dig-idaea-es-10261-217106
record_format koha
spelling dig-idaea-es-10261-2171062021-10-26T10:49:54Z Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper Ferrer-Cid, Pau Barceló-Ordinas, José María García Vidal, Jorge Ripoll, Anna Viana, Mar European Commission Viana, Mar [0000-0002-4073-3802] Air pollution Calibration http://aims.fao.org/aos/agrovoc/c_228 http://aims.fao.org/aos/agrovoc/c_36549 http://aims.fao.org/aos/agrovoc/c_28279 Polución del aire Calibración Sensores The data folder is includes the five different data sets used in the paper along with a metadata file, where the different features are explained. This dataset contains python scripts to calibrate tropospheric ozone sensor data obtained in the H2020 Captor project using sensor fusion techniques. Four different models are implemented; Multiple Linear Regression (MLR), K-Nearest Neighbors (KNN),Random Forest(RF) and Support Vector Regression (SVR). The methodology consists of first applying the PLS procedure to derive orthogonal components (to avoid multicollinearity problems). Afterwards, the components are used as features in the machine learning algorithms, so the models are trained. The scripts available in this repository have been used in the elaboration of the paper: "Multi-sensor data fusion calibration in IoT air pollution platforms" submitted to the IEEE Internet of Things journal. National Spanish funding; Regional Project; EU H2020 CAPTOR Project; AGAUR SGR44; 10.13039/501100011033-Agencia Estatal de Investigación; Spanish Ministry of Economy, Industry and Competitiveness Peer reviewed 2020-07-27T16:28:33Z 2020-07-27T16:28:33Z 2020 dataset http://purl.org/coar/resource_type/c_ddb1 http://hdl.handle.net/10261/217106 10.20350/digitalCSIC/12563 http://dx.doi.org/10.13039/501100000780 en #PLACEHOLDER_PARENT_METADATA_VALUE# info:eu-repo/grantAgreement/EC/H2020/688110 Script execution examples: Machine Learing The different methods can be executed by executing the python scripts {Method}_Calib_Pandas_CMD_PLS.py. If you want to add more sensors to calibrate you should change the "sensors" constant and add the sensor names as they appear in the CSV File. Moreover, the temperature and relative humidity fields must be named "Temp" and "RH" respectively in the CSV file. Execution: $ python {Method}_Calib_Pandas_CMD_PLS.py -f data_file -n name_for_results -p place -s array_sensors_to_calibrate Here is an execution example: $ python MLR_Calib_Pandas_CMD_PLS.py -f fusion_manlleu_supervised.csv -n manlleu_2 -p MANLLEU -s 01 The input file is: fusion_manlleu_supervised.csv. The first two sensors present in the csv file ( -s 01) are calibrated. Script execution examples: Weighted Averages File "Calib_CAPTOR_Classes.py" contains the function "sensor_combination_weighted_averages(errors, y_hat_test)", in which provided the errors of the different sensors in the training set and the sensors predictions or the test set, returns the set of computed weights and the test predictions for the fusion. Sí open
institution IDAEA ES
collection DSpace
country España
countrycode ES
component Bibliográfico
access En linea
databasecode dig-idaea-es
tag biblioteca
region Europa del Sur
libraryname Biblioteca del IDAEA España
language English
topic Air pollution
Calibration
http://aims.fao.org/aos/agrovoc/c_228
http://aims.fao.org/aos/agrovoc/c_36549
http://aims.fao.org/aos/agrovoc/c_28279
Polución del aire
Calibración
Sensores
Air pollution
Calibration
http://aims.fao.org/aos/agrovoc/c_228
http://aims.fao.org/aos/agrovoc/c_36549
http://aims.fao.org/aos/agrovoc/c_28279
Polución del aire
Calibración
Sensores
spellingShingle Air pollution
Calibration
http://aims.fao.org/aos/agrovoc/c_228
http://aims.fao.org/aos/agrovoc/c_36549
http://aims.fao.org/aos/agrovoc/c_28279
Polución del aire
Calibración
Sensores
Air pollution
Calibration
http://aims.fao.org/aos/agrovoc/c_228
http://aims.fao.org/aos/agrovoc/c_36549
http://aims.fao.org/aos/agrovoc/c_28279
Polución del aire
Calibración
Sensores
Ferrer-Cid, Pau
Barceló-Ordinas, José María
García Vidal, Jorge
Ripoll, Anna
Viana, Mar
Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper
description The data folder is includes the five different data sets used in the paper along with a metadata file, where the different features are explained.
author2 European Commission
author_facet European Commission
Ferrer-Cid, Pau
Barceló-Ordinas, José María
García Vidal, Jorge
Ripoll, Anna
Viana, Mar
format dataset
topic_facet Air pollution
Calibration
http://aims.fao.org/aos/agrovoc/c_228
http://aims.fao.org/aos/agrovoc/c_36549
http://aims.fao.org/aos/agrovoc/c_28279
Polución del aire
Calibración
Sensores
author Ferrer-Cid, Pau
Barceló-Ordinas, José María
García Vidal, Jorge
Ripoll, Anna
Viana, Mar
author_sort Ferrer-Cid, Pau
title Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper
title_short Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper
title_full Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper
title_fullStr Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper
title_full_unstemmed Calibration Software and Data Sets used in: "Multi-sensor data fusion calibration in IoT air pollution platforms" paper
title_sort calibration software and data sets used in: "multi-sensor data fusion calibration in iot air pollution platforms" paper
publishDate 2020
url http://hdl.handle.net/10261/217106
http://dx.doi.org/10.13039/501100000780
work_keys_str_mv AT ferrercidpau calibrationsoftwareanddatasetsusedinmultisensordatafusioncalibrationiniotairpollutionplatformspaper
AT barceloordinasjosemaria calibrationsoftwareanddatasetsusedinmultisensordatafusioncalibrationiniotairpollutionplatformspaper
AT garciavidaljorge calibrationsoftwareanddatasetsusedinmultisensordatafusioncalibrationiniotairpollutionplatformspaper
AT ripollanna calibrationsoftwareanddatasetsusedinmultisensordatafusioncalibrationiniotairpollutionplatformspaper
AT vianamar calibrationsoftwareanddatasetsusedinmultisensordatafusioncalibrationiniotairpollutionplatformspaper
_version_ 1777669442042331136